The Performance and Vulnerability of Foundation Structures
Course Overview
As the name implies, in a shallow foundation the base of the foundation where the loads from the structure are transferred to the underlying soil is at relatively shallow depth, close to the ground surface. Compared to shallow foundations, deep foundations are usually more costly and therefore are generally used when soil conditions are not suitable for shallow foundations, e.g. at site with compressible soils in order to minimize potential settlement problems. Deep foundations can be categorized into pile foundations (including drilled shafts in the context of this document) and caisson foundations. Pile foundations can be subdivided into various sub categories in terms of the pile sizes (i.e. pile diameters), number of piles in a group (large groups, small groups), types (e.g. reinforced concrete, steel, timber), installation method (e.g. drilled, driven), and how they are connected to the superstructure (e.g. embedded pile footings, pile extensions, pile footings cantilevered above the mudline). Retaining walls can be broadly classified as walls that retain fills and walls that retain cuts. Walls that retain fill include gravity, semi-gravity, prefabricated modular, and mechanically stabilized earth (MSE) walls. The gravity, semi-gravity, and prefabricated modular walls are considered to be externally stabilized walls while MSE walls are considered to be internally stabilized walls. Walls that retain cuts include non-gravity cantilever, anchored, soil nail, and micro-pile walls. Non-gravity cantilever and anchored walls are considered to be externally stabilized while soil nail and micro-pile walls are considered to be internally stabilized. In current practice, LRFD seismic design of bridge abutments is often based on a displacement performance philosophy. This type of design necessitates that the geotechnical engineer predict the resistance of the abutment backfill soils to large displacements. Buried structures, in general, have performed better during earthquakes than have above ground structures such as bridges and buildings. Buried structures are constrained by the surrounding ground and, in general, cannot be excited independent of the ground or be subject to strong vibratory amplification, such as the inertial response of a bridge structure during earthquakes. This course material is based on FHWA Publication Number FHWA-NHI-11-032: LRFD Seismic Analysis and Design of Transportation Geotechnical Features and Structural Foundations Chapter Number 9, Chapter Number 10, Chapter Number 11, Chapter Number 12, and Chapter Number 13.
Learning Objectives
Course Writer
- EduMind, Inc
Applicable States
- Alabama
- Alaska
- Arizona
- Arkansas
- California
- Colorado
- Connecticut
- Delaware
- District of Columbia
- Florida
- Georgia
- Hawaii
- Idaho
- Illinois
- Indiana
- Iowa
- Kansas
- Kentucky
- Louisiana
- Maine
- Maryland
- Massachusetts
- Michigan
- Minnesota
- Mississippi
- Missouri
- Montana
- Nebraska
- Nevada
- New Hampshire
- New Jersey
- New Mexico
- New York
- North Carolina
- North Dakota
- Ohio
- Oklahoma
- Oregon
- Pennsylvania
- Puerto Rico
- Rhode Island
- South Carolina
- South Dakota
- Tennessee
- Texas
- Utah
- Vermont
- Virginia
- Washington
- West Virginia
- Wisconsin
- Wyoming